Basic Info.
Model NO.
35kv/1000kVA Three-phase epoxy resin poured dry ty
Usage
Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
Zhi Feng
Attachment
Fan, Housing
Insulation Class
H Grade
Shell
IP20/IP23
Authentication
ISO9001
Transport Package
Wooden Box
Specification
1406x860x1280mm
Trademark
Zhifeng Transformer
Origin
China
HS Code
8504210000
Production Capacity
100 Pieces/Month
Product Description
Company profile
Shandong Zhifeng Transformer Co., Ltd. is located in the North Rainbow Industrial Park, East Second Ring Road, Linqing City, Shandong Province, a famous canal city, with convenient transportation and beautiful environment. The company covers an area of 45,000 square meters, is a collection of 35KV and below oil-immersed transformer, dry transformer, special transformer, grounding transformer, arc suppression coil, reactor, box-type substation, American box transformer, all kinds of box production, sales, research and development in one of the professional power equipment manufacturing enterprises.
Product introduction
This series product uses in the 20kV,35kV electrical network power source reducing is directly the 400V power distribution power source or the 10kV electric transmission power source is the user power supply,because has the remarkable merit,uses for more and more many projects.Its main merit indludes:
1.The reduced occupying a land area of and multistage changes the electricity engineering construction,has the remarkable social efficiency.2.Saves the project investment,enhances the economic efficiency.
3.Simplifies the 10kV power transformer link,causes the movement maintenance cost to reduce obviously.
4.Uses the high-pressured undercurrent to replace the low pressure big electric current electric transmission,reducesthe line loss,reduces the / ine movement cost.
5.The 35kV,20kV power source enters directly uses electricity the center,enhances the power supply effectively the reliability.
Structural characteristics
Because the dry transformer has the advantages of strong short-circuit resistance, small maintenance workload, high operation efficiency, small volume, low noise, it is often used in places with high performance requirements such as fire prevention and explosion protection.
1. Safe, fireproof, pollution-free, can be directly operated in the load center;
2. Using domestic advanced technology, high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability, long service life;
3. Low loss, low noise, obvious energy-saving effect, maintenance-free;
4. Good heat dissipation performance, strong overload capacity, can improve capacity operation when forced air cooling;
5. Good moisture resistance, adapt to high humidity and other harsh environment operation;
6. Dry transformer can be equipped with perfect temperature detection and protection system. The intelligent signal temperature control system can automatically detect and display the working temperature of the three-phase winding, automatically start and stop the fan, and have alarm, trip and other functions.
7. Small size, light weight, less space, low installation cost.
Iron core
The high quality cold-rolled grain-oriented silicon steel sheet is adopted, and the core silicon steel sheet is made of 45 degrees full oblique joint, so that the magnetic flux passes along the joint direction of the silicon steel sheet.
Characteristics of the product
The SC(B)10 series 20kV, 35kV non-excitation voltage regulation dry transformer produced by our company is a low loss product.
In line with the national standards GB6450, GB/T10228 and IEC726 requirements, and has the following characteristics:
1. High performance, low loss, for the type 9 series replacement products.
2. The selection of high-quality silicon steel sheet, while greatly reducing the magnetic flux density, reduce the operation of silicon steel sheet magnetostrictive weight, effectively reduce noise c
3. Optimize the high-voltage coil structure, improve the distribution of interlayer voltage and capacitance, greatly improve the impact ability of the product to withstand atmospheric overvoltage and operating overvoltage, and also improve the electric field distribution, so that the product is further reduced.
4. Temperature control system and air cooling device can be configured to automatically start the fan cooling device when the load is too large, effectively improving the overload capacity of the equipment.
Product parameter
35kV the level SC(B)10 series presses the distribution transformer performance parameter list without the excitation accent
Rated Capacity (kVA) | Connection group symbol | Voltage combination(kV) | Non-load Cufrent (%) | Under the different insulation heat-resisting rank load loses(W) | Non-load loss (W) | Short-circuit impedance (%) | ||||
high press (kV) | High pressure tapping range(%) | Low pressur (kV) | B(100ºC) | F(120ºC) | H(145°ºC) | |||||
50 | YynO Dyn11 | 35 ~ 38.5 | ±5 2×2.5 | 0.4 | 2.6 | 1350 | 1420 | 1520 | 450 | 6.0 |
100 | 2.2 | 1970 | 2080 | 2230 | 630 | |||||
160 | 1.6 | 2650 | 2810 | 3010 | 790 | |||||
200 | 1.6 | 3130 | 3320 | 3560 | 880 | |||||
250 | 1.4 | 3560 | 3800 | 4060 | 990 | |||||
315 | 1.4 | 4250 | 4510 | 4820 | 1170 | |||||
400 | 1.2 | 5090 | 5410 | 5770 | 1370 | |||||
500 | 1.2 | 6240 | 6650 | 7070 | 1620 | |||||
630 | 1.0 | 7260 | 7690 | 8260 | 1860 | |||||
800 | 1.0 | 8550 | 9120 | 9730 | 2160 | |||||
1000 | 0.8 | 9880 | 10450 | 11210 | 2430 | |||||
1250 | 0.7 | 12060 | 12730 | 13580 | 2830 | |||||
1600 | 0.7 | 14630 | 15480 | 16530 | 3240 | |||||
2000 | 0.7 | 17190 | 18240 | 19470 | 3820 | |||||
2500 | 0.7 | 20610 | 21850 | 23370 | 4450 |
35kV the level SC(B)10 series adjusts the dehydration pressing type power transformer performance parameter list without the excitation
Rated Capacity (kVA) | Connection group symbol | Voltage combination (kV) | Non-load current (%) | Under the different insulation heat- resisting rank load loses(VV) | Non-load loss (W) | Short-circuit impedance (%) | ||||
high pressure (kV) | High pressure tapping Irange% | Low pressure (kV) | B (100ºC) | (120ºC) | H (145ºC) | |||||
800 | Dyn11 Yd11 YynO | 35 ~ 38.5 | ±5 2×2.5 | 3.15 6 6.3 10 10.5 11 | 0.9 | 8930 | 9400 | 10070 | 4860 | 6.0 |
1000 | 0.9 | 10260 | 10920 | 11680 | 2250 | |||||
1250 | 0.8 | 12160 | 12920 | 13770 | 2673 | |||||
1600 | 0.8 | 14630 | 15480 | 16530 | 3130 | |||||
2000 | 0.7 | 17190 | 18240 | 19570 | 3690 | 7.0 | ||||
2500 | 0.7 | 20610 | 21850 | 23370 | 4230 |
Rated Capacity (kVA) | Connection group symbol | Voltage combination (kV) | Non-load current (%) | Under the different insulation heat resisting rank load loses(VV) | Non-load loss (W) | Short- circuit impedance (%) | ||||
high pressure (kV) | High pressure tapping range % | Low pressure (kv) | B (100ºC) | F (120ºC) | H (145°ºC) | |||||
3150 | Dyn11 Yd11 YynO | 35 ~ 38.5 | ±5 2×2.5 | 3.15 6 6.3 10 10.5 11 | 0.6 | 23080 | 24510 | 26120 | 6030 | 8.0 |
4000 | 0.6 | 27930 | 29450 | 31350 | 7020 | |||||
5000 | 0.5 | 32960 | 34960 | 37330 | 8370 | |||||
6300 | 0.5 | 38470 | 40850 | 43600 | 9900 | |||||
8000 | Dyn11 Yd11 YNd11 | 0.4 | 43410 | 46070 | 49300 | 11340 | 9.0 | |||
10000 | 0.4 | 52720 | 55570 | 59470 | 12960 | |||||
12500 | 6 6.3 10 10.5 11 | 0.3 | 60800 | 64600 | 69060 | 15750 | ||||
16000 | 0.3 | 71720 | 76000 | 80560 | 19350 | |||||
20000 | 0.3 | 80750 | 85500 | 91480 | 22950 | 10.0 |
Transformer core
1, the core adopts high permeability and high-quality grain orientation cold rolled silicon steel, using 45° five-step overlap method to reduce no-load loss and no-load current.
2, the core design adopts simulation analysis method, accurate and effective calculation of vibration frequency and amplitude.
3, the iron core and the coil, the iron core and the clamp between the flexible connection. Through these measures, the noise level of the transformer is increased by 10-15dB compared to conventional products.
Application scenario
Dry transformers are widely used in local lighting, high-rise buildings, airports, terminals, CNC machinery and equipment and other places, simply said dry transformers refers to the iron core and winding is not impregnated in insulation oil transformer.
Cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under the rated capacity. When forced air cooling, the transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Due to the large increase in load loss and impedance voltage during overload, it is in a non-economic operation state, so it should not be kept in continuous overload operation for a long time.
Cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under the rated capacity. When forced air cooling, the transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Due to the large increase in load loss and impedance voltage during overload, it is in a non-economic operation state, so it should not be kept in continuous overload operation for a long time.
Field installation scenario
Production workshop
Packaging and transportation
Certification certificate
Frequently asked question
Q: Are you a manufacturer, factory or trading company?
A: Yes, we have been engaged in the development, production and operation of transformers for more than 15 years.
Q: What is your warranty?
A: We offer a 12-month warranty.
Q: Production time?
A: 30 to 45 days or depending on order requirements.
Q: What are your payment terms?
A: T/T, L/C or negotiation.
Q: How does your factory conduct quality control?
A: We carry out 100% QC inspection to ensure that every product is qualified. From raw material to final product manufacturing process, we have more than 10 QC inspections.
Q: Do you have any products in stock?
A: Not normally. All our products are manufactured according to your order quantity.
Q: What does a custom transformer need to provide?
A: Technical drawings and technical specification documents are best, or you can tell us some detailed technical specification dates below "Quote and order required information".
Q: Can I have a catalogue and price list for my MOQ trial order?
A: All of our products are made in China or displayed on the official website, you are always welcome to ask us directly for more information.