Basic Info.
Model NO.
S11-M
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EE
Brand
Zhibo
Frequency
50/60Hz
Standard
IEC60076
No. of Phase
Single/ Three Phases
Winding Material
Copper or Alumnium
Rated Power
50~31500kVA
Voltage
6.3~66kv
Core Material
Cold Rolled Grain Oriented Silicon Steel
Package
Plywooden or Nude Suitable to Be Delivered
Service Condition
Outdoor
Color of Tank
Gray/Grey or Green
Tapping
off Load or on-Load Tapping
Tapping Steps
Five Steps or Three Steps
Insulation Oil
Mineral Oil
Transport Package
Plywood
Specification
L*W*H
Trademark
zhibo
Origin
Guangdong China
Production Capacity
3000units/Year
Product Description
Quick details:
Custom attributes:
Product commerce clause:
Product Description:
Technical parameter:
PS: the weight and dimension just for reference, please in kind prevail.
Winding & active part:
Testing:
Package:
Logistics Delivery:
Company Profile:
Our Factory:
Business Cooperation:
Certification:
Brand Name: | ZHIBO |
Model Number: | S11-10KV series |
Certification: | ISO9001 |
Place of Origin: | China |
Custom attributes:
Product Name: | S11 series | Installation: | Indoor/Outdoor |
Rated Capacity: | 30~31500KVA | Voltage: | 6kv-35kv |
Number of Phases: | Single or Three Phases | Frequency: | 50Hz/60Hz |
Cooling: | ONAN/ONAF | Coil: | Copper/Aluminum Coil |
Insulation level: | Class H/F | Core: | Cold Rolled Grain Oriented Silicon Steel Sheet |
Product commerce clause:
Minimum Order Quantity: | 1Unit |
Price: | negotiation |
Payment Terms: | T/T ;L/C;USD |
Supply Ability: | 500 units per month |
Delivery Time: | 20 working days after received your payment |
Packaging Details: | plywooden box or nude, suitable to be delivered |
Product Description:
Voltage Available: 10kV, 11kV, 20kV,22kV,33kV,35kV...
The heat dissipation of transformer coil in new type series transformer S9 & S11 uses new oil duct structure with reasonable design, optimizes the insulation technology and improves the mechanical strength and snti short circuit ability. The core is made of high quality cold rolled sillcon steel, with five step lamination process, the surface coating curing paint to reduce the loss and noise. The apprearance is beautiful, easy and reliable operation.
The heat dissipation of transformer coil in new type series transformer S9 & S11 uses new oil duct structure with reasonable design, optimizes the insulation technology and improves the mechanical strength and snti short circuit ability. The core is made of high quality cold rolled sillcon steel, with five step lamination process, the surface coating curing paint to reduce the loss and noise. The apprearance is beautiful, easy and reliable operation.
Technical parameter:
GENERAL TRANSFORMER SPECIFICATION | |||
GENERAL SPECIFICATION | |||
TRANSFORMER TYPE | Oil Type | ||
INSTALLATION | Outdoor | ||
APPLICABLE STANDARDS | IEC 60076 | ||
RATED POWER | (ONAN) | kVA | 125 |
HIGH VOLTAGE | kV | 35 | |
HIGH VOLTAGE TAPPINGS (NO LOAD) | % | kV | ±2x2.5 or ±5% |
LOW VOLTAGE ( NO LOAD) | kV | 0.4 | |
HIGH VOLTAGE INSULATION LEVEL | (Um/UAC/ULI) | kV | 40/75/175 |
LOW VOLTAGE INSULATION LEVEL | (Um/UAC/ULI) | kV | 1 , 1 / 3 / -- |
FREQUENCY | HZ | 50 or 60 | |
VECTOR GROUP | Dyn11 | ||
NUMBER OF PHASES | 3 | ||
MAX. AMBIENT TEMPERATURE | C | 40 | |
MAX. TEMPERATURE RISE ( WINDING / OIL) | C | 65 / 60 | |
MAX. ALTITUDE ABOVE SEA LEVELL | m | 1000 | |
PERMISABLE SHORT CIRCUIT DURATION | s | 2 | |
GUARANTEED VALUES | |||
IMPEDENCE VOLTAGE (75C) | ±10% tolerance | % | 4.0 |
NO LOAD LOSSES | 15% tolerance | W | 240 |
LOAD LOSSES (75C) | 15% tolerance | W | 1890/1800 |
STRUCTURAL SPECIFICATIONS | |||
HIGH VOLTAGE WINDING CONDUCTOR MATERIALS | Cu | ||
LOW VOLTAGE WINDING CONDUCTOR MATERIALS | Cu | ||
OIL TYPE | Mineral Transformer Oil | ||
TANK MATERIALS | Steel Metal | ||
DIMENSION and WEIGHT | |||
LENGTH /WIDTH / HEIGHT | mm | L / W / H | |
TOTAL WEIGHT | kg | ||
WEIGHT OF ACTIVE PART | kg | ||
WEIGHT OF OIL | kg | ||
CONNECTION TERMINALS | |||
HIGH VOLTAGE | Proclean Bushings | ||
LOW VOLTAGE | Proclean Bushings | ||
ACCESSORIES | |||
HERMITICAL PROTECTION RELAY | yes | ||
PRESSURE RELIEF DEVICE | yes | ||
OFF-CIRCUIT TAP CHANGER | yes | ||
LIFTING LUGS | yes | ||
OIL FILLING & DRAIN VALVES | yes |
Winding & active part:
Testing:
Insulation measurement
Voltage ratio and vector group measurement
Winding resistance measurement
Applied impedance test
Induced over voltage withstand test
No load current and no load losses measurement
Short circuit impedance and load losses measurement
Voltage ratio and vector group measurement
Winding resistance measurement
Applied impedance test
Induced over voltage withstand test
No load current and no load losses measurement
Short circuit impedance and load losses measurement
Package:
Logistics Delivery:
Company Profile:
Our products are mainly including S9, S11, S13, SH15, SH16 series energy-saving oil-immersed transformers with 35kV and below voltages, which capacity are under 63000kVA; ZBW, YBW, YBM series combined substation; SC (B) 9, SC (B) 10, SC (B) 11 resin insulated low-loss dry-type transformers and SG (B) 10 series (H class) American DuPont NOMEX insulation transformers; ZS, ZSF series rectifier transformers, HSJ, HSSP series electric furnace transformers and so on.
There are a number of design experts in our company who could design according to the specific conditions of the equipment used by various steel companies, and they are well experienced in the design of special rectifier transformers and other products for power supply power transformers used in steel rolling projects. It can also ensure that the design has sufficient large load short-term overload tolerance. For the design and manufacturing process of rectifier transformers, we pay more attention to the factors that may occur due to the frequent impact of current and voltage for a long time due to the steel rolling process.
There are a number of design experts in our company who could design according to the specific conditions of the equipment used by various steel companies, and they are well experienced in the design of special rectifier transformers and other products for power supply power transformers used in steel rolling projects. It can also ensure that the design has sufficient large load short-term overload tolerance. For the design and manufacturing process of rectifier transformers, we pay more attention to the factors that may occur due to the frequent impact of current and voltage for a long time due to the steel rolling process.
Our Factory:
Business Cooperation:
Certification: