Jdzx10-10, 10kv Indoor Voltage Transformer PT 10√ 3/0.1√ 3/0.1/3, Accuracy Class and Protection Class 0.2/3p, 0.2/6p, 0.5/3p, 0.5/6p

Application: Instrument, Measurement and Protection
Type: Voltage Transformer
Phase: Single
Operation Condition: Indoor
Usage: Measurement and Protection
Winding Form: Multilayer Honeycomb Type

Products Details

Basic Info.

Model NO.
JDZX10-10
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use,Epoxy Resin,Sealed Structure
Transport Package
1PCS/CTN
Specification
GB 1208, ISO9001, CCC, IEC
Trademark
DHECN
Origin
China
HS Code
8504311000
Production Capacity
5000PCS/Month

Product Description

JDZX10-3,6,10 Type Voltage Transformer
Applications
JDZX10-3, 6, 10 Voltage Transformer is suitable for power measurement, current monitoring and relay protection in power system with Rated frequency 50Hz or 60Hz and Rated voltage 3-10kV. 
Applicable Standard: IEC60044-1, GB 1207
Type Designation
Jdzx10-10, 10kv Indoor Voltage Transformer PT 10√ 3/0.1√ 3/0.1/3, Accuracy Class and Protection Class 0.2/3p, 0.2/6p, 0.5/3p, 0.5/6p
Operation Conditions
Installation area: Indoor.
Ambient temperature: Max. temperature 40ºC;Min. temperature -5ºC;Daily average temperature can't exceed 30ºC.
Air conditions: No heavy pollution in air.
Technical Parameter
 
Model Rated voltage radio 
(kV)
Combined accuracy or Combined accuracy classes Rated output
(VA)
ltimate output
(VA)
Rated insulation level
(kV)
JDZX10-3 3/√3/0.1√3/0.1/3 0.2/6P(3P) 15/50 200 3.6/25/40
0.5/6P(3P) 30/50
JDZX10-6 6√3/0.1√3/0.1/3 0.2/6P(3P) 15/50 200 7.2/32//60
0.5/6P(3P) 30/50
JDZX10-10 10√3/0.1√3/0.1/3 0.2/6P(3P) 15/50 200 12/42/75
0.5/6P(3P) 30/50
 
Structure and Feature
The Voltage Transformer is of Post type. Its hermetically sealed by epoxy resin, with design advantages of anti-pollution, anti-damp, easy to be installed is also suitable for tropic area and free from special maintenace except periodically surface clean. Secondary outlet terminal is equipped with connection terminal box. Upside and profile of the box have a hole respectively. The two holes together with outlet terminal are for leading out. Six holes at the bottom of the PT are suitable for mounting.
 
Information Required for Order Placing
Model.
Rated voltage radio kV.
Combined accuracy classes and Rated output VA.