Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers

Application: Power, Electronic, Rectifier
Phase: Three
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001-2000, ISO9001, CCC

Products Details

  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
SGB10
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Low Frequency
Shape of Core
Ring
Tapping Range
±2X2.5%
Vector Group
Dyn11, Yyn0
High Voltage
20kv
Low Voltage
0.4kv
Rated Capacity
250kVA
Transport Package
Wooden Case / According Customers′ Demands
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504330000

Product Description

Product Description

 

Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers
FEATURES
1. High quality and high permeability silicon steel with a multi-stage stepping process leads to low no-load loss.
2. The surface adopting nano paint self-leveling process leads to low noise.
3. Strong waterproof and short-circuit resistance, strong overload capacity, good electrical performance, safety, and reliability.
4. Through the simulation analysis of the electric field, temperature field, and magnetic field, CEEG is the first company in China to pass KEMA's E2, C2, and F1 tests.
5. The product can adopt a dual-mode structure scheme to meet the needs of different customer groups.
6. Special intelligent transformer solutions and big data cloud diagnosis technology are adopted to be online from time to time.
Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers
Product Parameters

 

10kV Class SG(B)10 Product Data
Rated High Voltage:106)kV         Connection Symbol:Dyn11/Yyn0 
Nominal Low-voltage:0.4kV     Insulation level: L75 AC 35/LAC3      Tapping Range:±2×2.5%
 
Model No. UK  % Air loss PO(W) Load loss
 ( 120ºC) PK(W)
IO ( %) LPA (AN ) dB Gauge m*n SIZE
L*B*H(mm)
Body size
  (including feet)
Body weight
SG10-100 4% 400 1370 1.8 43 1215×860×1050 660 x660 675 1700 x1200 x1660
SG10-125 4% 470 1610 1.6 43 1215×860x1060 660 x660 720 1700 x1200 x1660
SGB10-160 4% 540 1850 1.6 44 1260×860×1130 660 x 660 890 1700 x 1200 x 1660
SGB10-200 4% 620 2200 1.4 44 1260×860×1105 660 x660 920 1700 x1200 x 1660
SGB10-250 4% 720 2400 1.4 46 1260×860×1130 660 x660 1050 1700 x 1200 x 1660
SGB10-315 4% 880 3730 1 47 1390×860×1155 660 x660 1410 1900 x1300 x1660
SGB10-400 4% 980 4280 1 48 1390×860×1375 820x660 1565 1900 x1300 x1660
SGB10-500 4% 1160 5230 1 49 1390×860×1390 820 x660 1680 1900 x1300x1660
SGB10-630 4% 1340 6290 0.85 51 1475×1020×1375 820x660 1800 2100x1400 x2015
SGB10-630 6% 1300 6400 0.85 51 1475×1020×1375 820 x660 1800 2100 x1400 x2015
SGB10-800 6% 1520 7460 0.85 52 1475×1020×1410 820x820 1930 2100 x1400 x2015
SGB10-1000 6% 1770 8760 0.85 52 1610×1020×1435 820 x820 2355 2100 x1400 x2015
SGB10-1250 6% 2090 10300 0.85 53 1610×1020×1630 820 x820 2940 2300x1500 x2120
SGB10-1600 6% 2450 12500 0.85 54 1790 x1150 x 1730 1070 x 1070 3540 2300 x 1500 x2120
SGB10-2000 6% 3050 15500 0.7 54 1790 x 1150 x1760 1070 x 1070 4050 2400 x 1500 x 2300
SGB10-2500 6% 3600 18400 0.7 55 1900x1150x1895 1070 x1070 4790 2600 x 1500 x2500
SGB10-3150 6% 4030 192200 0.7 57 2100 x 1150 x1960 1070 x 1070 6215 2600 x1500x2500

CERTIFICATED & QUALIFIED

SCB series cast resin dry-type transformers have reached the first-level energy efficiency standard of GB20052-2020, and won the 3C, PCCC energy-saving certification, ISO-9001, ISO-45001, and ISO-14001 certificates.
CEEG's cast resin dry-type power transformers have been widely adopted in key projects by customers from all over the world. For example, they have been chosen to serve in the Qingdao International Sailing Center, Beijing Urban sub-Center, Beijing Stadium the Skating Hall, Nanjing Metro, Shanghai EXPO Exhibition Center, etc.

Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers

DESIGN & MANUFACTURE PROCESS

Based on more than 30 years of design, manufacturing, and experimental experience in the transformer industry, CEEG has developed a set of advanced three-dimensional + parametric design software, which can realize automatic design, cost optimization, and simulation.
Fully considering the requirements of the national and industrial standards, ensuring the advantageous design of products.

The high-voltage winding conductor is wound with a high-quality conductor and reinforced with long and short-cut glass fiber felt. Poured by the advanced Heidrich vacuum pouring system under vacuum. Effectively restrain the occurrence of partial discharge, and the partial discharge is ≤ 5pc.

The low-voltage winding adopts a high-quality foil conductor and is wound on an automatic foil winding machine. The foil winding machine adopts the patented technology of foil wire hydraulic energy-saving tension crimping device, high-precision detection of ±0.5mm, and advanced argon arc welding technology, which plays a key role in ensuring the quality of coil winding.

The iron core adopts a high-quality high magnetic conductivity-oriented silicon steel sheet, a 45° full oblique step lapping process, and the surface adopts special moisture-proof and rust-proof coating, which effectively reduces the no-load current and noise level.
Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers
USE & PACKING

 SERVICE CONDITIONS - The installation site shall not be flooded by water, the altitude shall not exceed 1000m, and the ambient temperature shall not be higher than 40ºC. The relative humidity is 100%, and the environment is 40ºC to -25ºC (-25ºC requires an on-load tap changer and temperature controller).


PACKAGING & TRANSPORTATION - The products can be partially disassembled and transported (such as on-load tap changer, temperature controller, air cooling device, enclosure, etc. can be packaged separately) or packed as one piece in packaging boxes for transportation.


VISUAL INSPECTION BEFORE INSTALLATION - After opening the package, remove the protective device and check the external conditions, especially paying attention to the mechanical integrity of the coil and iron core, and the bolt fastening at the connection.


INSPECTION BEFORE OPERATION - Measure the DC resistance of high voltage and low voltage windings. Then check the grounding of the iron core to see whether the grounding is reliable and whether foreign matters are overlapping. Last to test the insulation resistance.

ENERGIZING - Before putting into operation, the transformer shall be put into trial operation under no-load, and the protection system shall be checked and adjusted after 3 times of impulse closing.
Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers




ABOUT CEEG

3 INDUSTRIAL ZONES 
4 FACTORIES
15 OVERSEAS BRANCHES
80+ GLOBAL MARKETS

THIS IS OUR DEVELOPMENT -  Headquartered in Nanjing, CEEG has always been adhering to the core values of "foresight, innovation, and responsibility" since its establishment in 1990, focusing on production and manufacturing for more than 30 years. In years of development, CEEG has Integrated independent research and development, intelligent manufacturing, and smart marketing services.

OUR PRODUCT - O
ur technical team has continued to explore and innovate boldly, and has successfully developed nearly a hundred products including evaporative transformers, load centers, 35kV amorphous dry transformers, nuclear power transformers, slow harmonic transformers, high-temperature transformers.

OUR PARTNERS - Our products have been safely operating in major coal groups such as Shenhua Group, Anhui Tongling Mining Group, Pingdingshan Coal Industry Group, Jincheng Coal Industry Group, and Kaolain Group. Many well-known companies such as China Mobile, China Telecom, Inner Mongolia First Machinery, Inner Mongolia Pingzhuang Energy, and Jialing Motor also have established good partnerships with us. We also established long-term strategic cooperative relations with excellent enterprises all over the world, and our business partners include many great companies such as DuPont, Siemens, Hitachi Metals, and ABB. Our power transformers have been sold to over 80 countries and regions and got high recognition from customers overseas.
Sg10 250kvahigh-Efficiency Solutions with Sg (B) Series Non-Encapsulated Dry-Type Transformers


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours